Filter Results By:

Products

Applications

Manufacturers

Showing results: 226 - 240 of 242 items found.

  • NI-9218, 51.2 kS/s/ch, 2-Channel C Series Universal Analog Input Module

    783367-01 - NI

    51.2 kS/s/ch, 2-Channel C Series Universal Analog Input Module - The NI‑9218 is designed for multipurpose measurements. It offers built-in support for accelerometer, powered sensor, full-bridge, and voltage measurements as well as quarter-bridge, half-bridge, 60 V, and current measurements using measurement-specific adapters. Each channel is individually selectable, so you can perform different measurements on each channel. The NI‑9218 is ideal for creating universal test systems for automotive, off-highway, and data-logging systems.

  • NI-9218, 51.2 kS/s/ch, 2-Channel C Series Universal Analog Input Module

    783362-01 - NI

    51.2 kS/s/ch, 2-Channel C Series Universal Analog Input Module - The NI‑9218 is designed for multipurpose measurements. It offers built-in support for accelerometer, powered sensor, full-bridge, and voltage measurements as well as quarter-bridge, half-bridge, 60 V, and current measurements using measurement-specific adapters. Each channel is individually selectable, so you can perform different measurements on each channel. The NI‑9218 is ideal for creating universal test systems for automotive, off-highway, and data-logging systems.

  • Digital Multimeter

    DMT-4010RMS - Monacor International GmbH & Co. KG

    *True RMS measurement method*Dust and water protection according to IP class 67 with covered measuring sockets*Auto ranging for faster measurements*4000 digit resolution*Additional bar display*Voltage measurement up to DC/˜ 1000 V*Current measurement up to DC/˜ 10 A*Frequency measurement up to 10 MHz*Resistance measurement up to 40 MΩ*Capacitance measurement up to 40 mF*Temperature measurement -20 °C to +760 °C*Acoustic continuity test*diode test*Data hold (measured value memory)*peak hold*Maximum and minimum value recording*LC display with switchable background lighting*Automatic shutdown*overload protection*Supplied with test leads and protective case

  • FD-11603, 8-Channel, ±10 V Voltage Input Device for FieldDAQ

    785639-01 - NI

    The FD-11603 can measure up to eight channels with a voltage input range of ±10 V. It features 24-bit resolution with simultaneous sample rates up to 100 kS/s. The FD-11603 offers channel-to-channel isolation, which eliminates noise from ground loops and protects instrumentation circuitry from high-transient voltages. The FD-11603 has an ingress protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11603 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11603 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. The FD-11603 is ideal for test cell and outdoor environments.

  • Broadband Calibrated Noise Sources

    Fairview Microwave Inc.

    Fairview Microwave’s calibrated noise sources cover frequency bands from 10 KHz to 18 GHz. Their performance specifications include output ENR levels ranging from 15 dB to 30 dB and typical VSWR levels as low as 1.25:1. Depending on the model, calibrated frequency points are at 10 MHz, 100 MHz, 1000 MHz, 2000 MHz and 1 GHz steps. The temperature coefficient of these noise sources is < 0.01 dB/°C and noise output variation is < 0.1 dB/%V.

  • Low-Profile 16-CH Isolated DI & 16-CH Isolated DO PCI Card

    LPCI-7230 - ADLINK Technology Inc.

    ADLINK LPCI-7230 is 32-CH isolated input and/or card. It provides a 2,500 C optical isolation protection. Two wide input range of the LPCI-7230 makes it easy to sense the status of external devices. The non-polarity characteristic is suitable for a wide variety of industry applications. The LPCI-7230 devices also feature a wide output range from 5 to 35 V, which is suitable for relay driving and industrial automations applications. The LPCI-7230 also provides two interrupt sources on digital input channels, which are easily user configurable.

  • 32-CH Isolated DIO Card

    LPCIe-7230 - ADLINK Technology Inc.

    ADLINK LPCIe-7230 is 32-CH isolated input and/or card. It provides a 2,500 C optical isolation protection. Two wide input range of the LPCIe-7230 makes it easy to sense the status of external devices. The non-polarity characteristic is suitable for a wide variety of industry applications. The LPCIe-7230 devices also feature a wide output range from 5 to 35 V, which is suitable for relay driving and industrial automations applications. The LPCIe-7230 also provides two interrupt sources on digital input channels, which are easily user configurable.

  • Digital AC/DC Auto-Ranging Clamp Meter

    PCMT20 - Pyle Audio Inc.

    Measures AC and DCMax. Resolution to Current Measurement: 0.1uALCD Display with BacklightData Hold, Zero Function, Auto Power OffLower Battery Indiactor0.9' (23mm) Jaw SizeDC Voltage: Range: 0-600 V; Accuracy: +/- 0.5%AC Voltage: Range: 0-600 V; Accuracy: +/- 1.5%AC Current: Range: 0-400 A; Accuracy: +/- 3.0%Resistance: Range: 0-40 M; Accuracy: +/- 3.0%Temperature: Range: 1000 C / 1832 F; Accuracy: +/- 3.0%Capacitance: Range: 100 uF; Accuracy: +/- 2.5%Frequency: Range: 150 kHz; Accuracy: +/- 1.2%Continuity: Buzzer Sounds at 100Diode: Test Current 0.3mA; Open Circuit Voltage 1.5VBatteries: 2 x AAA IncludedAccessories Included: Black Bag, Test Leads, Type K Temperature ProbeDimensions: 8.07' H x 2.36' W x 1.18' DWeight: 7.94 ozSold as : Unit

  • NI-9351, 4-Channel C Series Functional Safety Module

    784446-01 - NI

    4-Channel C Series Functional Safety Module - The NI-9351 works with 24 V industrial logic levels to directly connect to various sensor types, including light curtains, emergency e-stop buttons, and final elements such as relays, contactors, and motor drives. The NI-9351 is an analog input and digital I/O Functional Safety Module capable of SIL 3 certification according to IEC 61508. You can use the Functional Safety Editor to program the safety logic solver, which resides in the module. The module features diagnostics for monitoring the status of hardware and the integrity of the connections.

  • NI-9236, 10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module

    785996-01 - NI

    10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module - The NI‑9236 measures dynamic strain on all channels simultaneously, allowing for synchronized, high-speed measurements. This capability is important for applications, such as impact tests, that require comparison across many channels at a particular instant in time. The NI‑9236 includes built-in voltage excitation for quarter-bridge sensors. It also has 60 VDC isolation and 1,000 V rms transient isolation, providing high‑common‑mode noise rejection and increased safety.

  • NI-9236, 10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module

    779994-02 - NI

    10 kS/s/channel, 350 Ω Quarter-Bridge Strain Gage, 8-Channel C Series Strain/Bridge Input Module - The NI‑9236 measures dynamic strain on all channels simultaneously, allowing for synchronized, high-speed measurements. This capability is important for applications, such as impact tests, that require comparison across many channels at a particular instant in time. The NI‑9236 includes built-in voltage excitation for quarter-bridge sensors. It also has 60 VDC isolation and 1,000 V rms transient isolation, providing high‑common‑mode noise rejection and increased safety.

  • NI-9205, cDAQ-9171, and cRIO-9940 USB Voltage Measurement Bundle

    865683-01 - NI

    NI-9205, cDAQ-9171, and cRIO-9940 USB Voltage Measurement Bundle - The USB Voltage Measurement Bundle with NI-9205, cDAQ-9171, and cRIO-9940 includes the NI-9205 C Series Voltage Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the cRIO-9940 Backshell for strain relief and operator protection from high-voltage signals. The included NI-9205 features a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Additionally, the NI-9205 provides up to 60 V of overvoltage protection between input channels and common, and it is rated for 1,000 Vrms transient overvoltage protection.

  • Circuit Breaker Analyzers & Timers

    CAT Advanced Series - IBEKO Power AB

    DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.

  • Portable Sulphuric Acid Dewpoint Temperature Monitor

    Walsn Enterprises Ltd.

    The fuels used in boilers, such as coal, heavy oil and natural gas, contains S. during the combustion process, S and O₂ form SO₂, and a small amount of SO₂ is converted into SO₃ under catalysis of Fe₂O₃, V₂O₅ and other catalysts. Under normal circumstances, the volume of SO₃ in the boiler flue gas is 1×10-6~50×10-6, and the water vapor is about 10%. When the temperature of the flue gas is below 200°C, SO₃ and the water vapor are completely combined into H₂SO₄ vapor. A small amount of H₂SO4 vapor will significantly increases the acid dew point. When the surface temperature of the boiler heat exchange equipment is lower than the flue gas acid dew point, the H₂SO₄ vapor will condense on the surface to become sulfuric acid solution with a concentration of about 80%, which will adhere to the surface of the heat exchanger and cause acid corrosion. Typical equipment that is prone to corrosion includes air preheaters, induced draft fans and flue walls.

  • COMPUTERIZED AUTOMATIC RELAY TEST SYSTEM

    CVRT-S16 - Vasavi Electronics

    CVRT-S8 & S16 are ideal for automatic testing of ELECTRO MECHANICAL AND READ RELAYS (only DC relays) both for static and dynamic characteristics. This system scans at one stroke, all the parameters of the relay as per definition of test procedure. The test sequence can be pre-programmed and stored in the disk. You can select the tests as per your requirement. Can include or exclude the test and you can have several options to match your test definitions. Semi skilled person can be engaged for actual testing, as he need not make any settings and need not interpret the readings. The system conducts the tests and gives PASS / FAIL indication on overall test results. If a printer is connected, each test result will be printed.Test Parameters : -> Coil Resistance.-> PickUp/Pull In /Operating Voltage or Current Linear Ramp Method or Step Method.-> Measure Pickup Contact Gap FBB-LBB V or mA-> DropAway/Drop Out/Release Voltage or Current Linear Ramp Method or Step Method.-> DropAway Contact Gap FFB-LFB V or mA-> % Release Dropaway/Pickup-> Contact Resistance of all contacts both Front and Back contacts.-> Operating Time @ Set Voltage or Current.-> Contact Bounce or Chattering Time while Operating @ above-> Release Time @ Set Voltage or Current.-> Contact Bounce or Chattering Time while release @ above-> Difference of Operate Time - Release Time.-> Bridging Test or Non Overlap Test.-> Transfer or Traverse Times while Operate and release.-> Operate Time @2nd Set Voltage or Current.-> Release Time @2nd Set Voltage or Current.-> Power Consumption @ Rated Voltage.-> Coil Current @ Rated Voltage at Room Temperature.-> Coil Resistance Corrected to 20deg C.-> Timing Waveform Graph for all active Contacts.

Get Help